| Specifications: | |
| Peak Sewage Flow: | 600 gallons per day |
| Estimated Percolation Rate: | 55 minutes per inch (Class III Soils) |
| Septic Tank: | 1,200 gallon - concrete mid seam |
| Treatment Tank: | 1,000 gallon - top seam |
| Pump Chamber: | 1,000 gallon - top seam |
| AdvanTex Module: | AX-20 - one unit Module is time dosed for 30 seconds and rested for 9.5 minutes |
| Disposal Method: | Three 14'x 24' Gravel Beds = 1,008 square feet Beds are time dosed for 1 minute and rested for 90 minutes |
![]() Installation was performed by: Parsley Septic Company Located in James City County (757) 566-1784 |
![]() First pad fully installed. Pads were installed level to contour, at a maximum depth of 12". Each pad has a minimum of 6" of cover, were sloped to promote runoff, and seeded. |
![]() First half of 2nd pad installed. Notice 4" perforated pipe extending from end of pad to be connected to distribution system. |
![]() Final Grade & Seeding of Disposal Area. |
![]() Setting the 1,000 gallon top seam treatment tank. Risers were Pre-Cast and set prior to delivery. |
![]() AdvanTex AX-20 Module and Risers |
![]() AdvanTex AX-20 Module and Risers. |
![]() Installation of the Recirculation Splitter Valve connector and riser. |
![]() Wiring the AdvanTex Module and Pump Chamber |
![]() AdvanTex Module discharging to Pump Chamber for discharge to disposal beds. |
![]() Completed Installation |