| Specifications: | |
| Peak Sewage Flow: | 300 gallons per day |
| Estimated Percolation Rate: | <20 minutes per inch (Class I-II Soils) |
| Septic Tank: | 1,500 gallon - baffled, top seam |
| AdvanTex Module: | AX-20 - one unit Module is time dosed for 30 seconds and rested for 9.5 minutes |
| Disposal Method: | One Gravel Beds, gravity fed from the AdvanTex Treatment System |
Soils Evaluation by: Coastal Plains Environmental Group System Design by: Coastal Plains Environmental Group System Installed by: Churchview Septic Service 804.758.5836 |
![]() Pad fully installed. ![]() Contractor beginning to excavate hole for septic tank | |
![]() Use of a "Caisson" was required due to the high water table. |
![]() In this photo, you can see water running in under the Caisson. |
![]() 1,500 gallon top seam baffled septic tank & rail truck. |
![]() Lowering the septi tank into the void. |
![]() As the septic tank is being set, you can see the water filling the void space. |
![]() Setting the AdvanTex Module and Risers. |
![]() AdvanTex AX-20 Module and Risers. |
![]() Note the bags of cement used to help weigh the sysem down in the event of a high water event. |
![]() Pump Vault, Pump, and Float Tree assembly |
![]() Distribution Box to Pad |
![]() Completed Installation |