| Specifications: | |
| Peak Sewage Flow: | 600 gallons per day |
| Estimated Percolation Rate: | 20 minutes per inch (Class IIa Soils) |
| Treatment Tank: | 1,500 gallon baffled, concrete top seam |
| Pump Chamber: | 1,000 gallon - top seam |
| AdvanTex Module: | AX-20 - one unit Module is time dosed for 30 seconds and rested for 9.5 minutes |
| Disposal Method: | Single 20'x 20' Gravel Bed = 400 square feet Bed is time dosed for 1 minute and rested for 90 minutes |
Soils Evaluation by: Coastal Plains Environmental Group System Design by: Coastal Plains Environmental Group System Installed by: Churchview Septic Service 804.758.5836 |
![]() Beginning Pad Installation Setting Distribution Box & Header Lines. |
![]() Spreading the first load of gravel in pad area. |
![]() Pad almost completed. Note Perforated Pipe used to disperse effluent. |
![]() Pad completed. We use heavy fabric instead of paper to keep fines from settling into the gravel. |
![]() Close up of Distribution Box - Note extra ports will allow for expansion if necessary. |
![]() Beginning final grade over drainfield area. |
![]() 1,000 gallon top seam pump chamber. Contractor getting ready to go Tank Diving after a dropped tool. |
![]() Tool Retrieved Contractor Comments: This *&%#$@&* water is COLD! |
![]() AdvanTex AX-20 Module and Risers. |
![]() Split Flow Tee installation, Shows piping from AdvanTex Module and piping to pump chamber. |
![]() Pump Control panel and AdvanTex passive air vent. |
![]() AdvanTex Module discharging to Pump Chamber for discharge to disposal beds. |
![]() Completed Installation |