These photographs and specifications are from a three bedroom residential system, that had a failure to its original drainfield. The available area with suitable soils was extremely limited. Design called for a shallow placed pad installed at 12".

The owners requested an AdvanTex Treatment System so as to be able to use the minimum area available, and to increase the residential size from a three bedroom to a four bedroom residence in the future. Installation consisted of a single 1,500 gallon baffled concrete tank to be used as both the primary treatment (septic tank) and the processing tank for the AdvanTex Treatment System. A 1,000 gallon concrete top seam tank was used as the pump chamber, allowing for an 18 hour operating volume and a quarter day reserve capacity.


Specifications:
Peak Sewage Flow:600 gallons per day
Estimated Percolation Rate:20 minutes per inch (Class IIa Soils)
Treatment Tank:1,500 gallon baffled, concrete top seam
Pump Chamber:1,000 gallon - top seam
AdvanTex Module:AX-20 - one unit
Module is time dosed for 30 seconds and rested for 9.5 minutes
Disposal Method:Single 20'x 20' Gravel Bed = 400 square feet
Bed is time dosed for 1 minute and rested for 90 minutes



Soils Evaluation by:
Coastal Plains Environmental Group

System Design by:
Coastal Plains Environmental Group

System Installed by:
Churchview Septic Service
804.758.5836


Beginning Pad Installation
Setting Distribution Box
& Header Lines.

Spreading the first load
of gravel in pad area.


Pad almost completed.
Note Perforated Pipe used
to disperse effluent.


Pad completed.
We use heavy fabric instead
of paper to keep fines from
settling into the gravel.

Close up of Distribution
Box - Note extra ports
will allow for expansion
if necessary.

Beginning final grade
over drainfield area.

1,000 gallon top seam
pump chamber.
Contractor getting ready to go
Tank Diving after a dropped tool.



Tool Retrieved

Contractor Comments:

This *&%#$@&* water is COLD!


AdvanTex AX-20 Module
and Risers.


Split Flow Tee installation,
Shows piping from AdvanTex Module
and piping to pump chamber.

Pump Control panel
and AdvanTex passive
air vent.

AdvanTex Module discharging to
Pump Chamber for discharge to
disposal beds.